Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables

Model NO.: NYRY
Wire Core Material: Copper
Certification: CCC, CE
Model: Nyby, Nyry
Brand: Jl
Rated Voltage: 0.6/1 Kv
Number of Core: 1-5
Refer Standard: IEC 60502-1
Type of Armor: Swa or Sta
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-400 Mm2
Origin: Jiangsu, China
HS Code: 8544492100
Model NO.: NYRY
Wire Core Material: Copper
Certification: CCC, CE
Model: Nyby, Nyry
Brand: Jl
Rated Voltage: 0.6/1 Kv
Number of Core: 1-5
Refer Standard: IEC 60502-1
Type of Armor: Swa or Sta
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 1.5-400 Mm2
Origin: Jiangsu, China
HS Code: 8544492100
Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables

Low Voltage PVC Insulated Power Armoured Cables
Construction:
Copper or Aluminum Conductor , PVC Insulation, Aluminum/galvanized steel wires or Double Steel /Aluminum Tape Armour, PVC Sheathed

Low Voltage PVC Insulated Power Armoured Cables Application:
IEC 60502-1 cables are used for electricity supply in low voltage installation system, IEC 60502-1 cables are
suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.

Low Voltage PVC Insulated Power Armoured Cables Colour Code:
1 Core :  Red or Black
2 Cores :  Red, Black
3 Cores :  Red, Yellow, Blue
4 Cores :  Red, Yellow, Blue, Black
5 Cores :  Red, Yellow, Blue, Black, Green
Above 5 Cores:  Black Cores with White numerals
Colour Code (2) :
1 Core : Brown or Blue
2 Cores :  Brown or Blue
3 Cores : Brown, Black, Grey
4 Cores :  Blue, Brown, Black, Grey
5 Cores :  Green/Yellow, Blue, Brown, Black, Grey
Above 5 Cores: Black Cores with White numerals

Low Voltage PVC Insulated Power Armoured Cables Technical Data:
Conductor:   Copper or Aluminium conductor, round standed or Shaped,solid round conductor(Class1)or stranded Conductor(Class2) ,
Test Voltage:  4000V
Working Temperature:-5-70 º C
Short-circuit max. Conductor temperature:160°C
Insulation resistance: 20 MΩ x km

Parameter:

Two cores(Galvanized steel wire armoured)
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2x2.5 1.8 0.8 1 0.8 1.8 14
2x4 2.3 1 1 1.25 1.8 16.7
2x6 2.8 1 1 1.25 1.8 17.7
2x10 3.6 1 1 1.25 1.8 19.3
2x16 4.5 1 1 1.25 1.8 21.1
2x25 5.6 1.2 1 1.6 1.8 24.8
2x35 6.7 1.2 1 1.6 1.8 27
2x50 8 1.4 1 1.6 1.9 30.7
2x70 9.4 1.4 1 2 2.1 34.5
2x95 11 1.6 1.2 2 2.2 39.2
2x120 12.4 1.6 1.2 2 2.3 42.2
2x150 13.8 1.8 1.2 2.5 2.5 47.2
2x185 15.3 2 1.4 2.5 2.6 51.6
2x240 17.5 2.2 1.4 2.5 2.8 57.2
2x300 19.5 2.4 1.6 2.5 3 62.8
2x400 22.6 2.6 1.6 2.5 3.2 70.3



Three cores(Galvanized steel wire armoured)
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
   
mm² mm mm mm mm mm mm    
3x2.5 1.8 0.8 1 0.8 1.8 14.5    
3x4 2.3 1 1 1.25 1.8 17.4    
3x6 2.8 1 1 1.25 1.8 18.4    
3x10 3.6 1 1 1.25 1.8 20.2    
3x16 4.5 1 1 1.6 1.8 22.8    
3x25 5.6 1.2 1 1.6 1.9 26    
3x35 6.7 1.2 1 1.6 1.9 28.5    
3x50 8 1.4 1 2 2 33.3    
3x70 9.4 1.4 1.2 2 2.1 37    
3x95 11 1.6 1.2 2 2.3 41.6    
3x120 12.4 1.6 1.2 2.5 2.4 45.9    
3x150 13.8 1.8 1.4 2.5 2.6 50.4    
3x185 15.3 2 1.4 2.5 2.7 54.8    
3x240 17.5 2.2 1.5 2.5 2.9 61.2    
3x300 19.5 2.4 1.6 2.5 3.1 66.8    
3x400 22.6 2.8 1.6 3.15 3.4 76.7    
3x500 25.2 2.8 1.8 3.15 3.7 83.6    
                 
Three cores+1(Galvanized steel wire armoured)    
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x10 +6 3.6 2.8 1 1 1 1.25 1.8 21.9
3x16 +10 4.5 3.6 1 1 1 1.6 1.8 24.2
3x25 +16 5.6 4.5 1.2 1 1 1.6 1.8 27.9
3x35 +16 6.7 4.5 1.2 1 1 1.6 1.9 30.8
3x50 +25 8 5.6 1.4 1.2 1 2 2 36.4
3x70 +35 9.4 6.7 1.4 1.2 1.2 2 2.1 40.1
3x95 +50 11 8 1.6 1.4 1.2 2.5 2.3 46.3
3x120 +70 12.4 9.4 1.6 1.4 1.4 2.5 2.4 50.3
3x150 +70 13.8 9.4 1.8 1.4 1.4 2.5 2.6 55
3x185 +95 15.3 11 2 1.6 1.4 2.5 2.7 60.3
3x240 +120 17.5 12.4 2.2 1.6 1.6 2.5 2.9 67

Four cores(Galvanized steel wire armoured)
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4x4 2.3 1 1 1.25 1.8 18.5
4x6 2.8 1 1 1.25 1.8 19.7
4x10 3.6 1 1 1.25 1.8 22.3
4x16 4.5 1 1 1.6 1.8 24.5
4x25 5.6 1.2 1 1.6 1.9 28.2
4x35 6.7 1.2 1 1.6 2 31.1
4x50 8 1.4 1 2 2.1 36.7
4x70 9.4 1.4 1.2 2 2.3 40.4
4x95 11 1.6 1.2 2.5 2.5 46.6
4x120 12.4 1.6 1.4 2.5 2.6 50.6
4x150 13.8 1.8 1.4 2.5 2.7 55.3
4x185 15.3 2 1.4 2.5 2.9 60.6
4x240 17.5 2.2 1.6 2.5 3.1 67.3
4x300 19.5 2.4 1.6 3.15 3.4 74.9
4x400 22.6 2.6 1.8 3.15 3.7 84.4
4x500 25.2 2.8 2 3.15 3.9 92.1

Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables
Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables
Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables
Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables
Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables






  Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables

Low Voltage PVC Insulated Power Armoured Cables
Construction:
Copper or Aluminum Conductor , PVC Insulation, Aluminum/galvanized steel wires or Double Steel /Aluminum Tape Armour, PVC Sheathed

Low Voltage PVC Insulated Power Armoured Cables Application:
IEC 60502-1 cables are used for electricity supply in low voltage installation system, IEC 60502-1 cables are
suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.

Low Voltage PVC Insulated Power Armoured Cables Colour Code:
1 Core :  Red or Black
2 Cores :  Red, Black
3 Cores :  Red, Yellow, Blue
4 Cores :  Red, Yellow, Blue, Black
5 Cores :  Red, Yellow, Blue, Black, Green
Above 5 Cores:  Black Cores with White numerals
Colour Code (2) :
1 Core : Brown or Blue
2 Cores :  Brown or Blue
3 Cores : Brown, Black, Grey
4 Cores :  Blue, Brown, Black, Grey
5 Cores :  Green/Yellow, Blue, Brown, Black, Grey
Above 5 Cores: Black Cores with White numerals

Low Voltage PVC Insulated Power Armoured Cables Technical Data:
Conductor:   Copper or Aluminium conductor, round standed or Shaped,solid round conductor(Class1)or stranded Conductor(Class2) ,
Test Voltage:  4000V
Working Temperature:-5-70 º C
Short-circuit max. Conductor temperature:160°C
Insulation resistance: 20 MΩ x km

Parameter:

Two cores(Galvanized steel wire armoured)
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2x2.5 1.8 0.8 1 0.8 1.8 14
2x4 2.3 1 1 1.25 1.8 16.7
2x6 2.8 1 1 1.25 1.8 17.7
2x10 3.6 1 1 1.25 1.8 19.3
2x16 4.5 1 1 1.25 1.8 21.1
2x25 5.6 1.2 1 1.6 1.8 24.8
2x35 6.7 1.2 1 1.6 1.8 27
2x50 8 1.4 1 1.6 1.9 30.7
2x70 9.4 1.4 1 2 2.1 34.5
2x95 11 1.6 1.2 2 2.2 39.2
2x120 12.4 1.6 1.2 2 2.3 42.2
2x150 13.8 1.8 1.2 2.5 2.5 47.2
2x185 15.3 2 1.4 2.5 2.6 51.6
2x240 17.5 2.2 1.4 2.5 2.8 57.2
2x300 19.5 2.4 1.6 2.5 3 62.8
2x400 22.6 2.6 1.6 2.5 3.2 70.3



Three cores(Galvanized steel wire armoured)
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
   
mm² mm mm mm mm mm mm    
3x2.5 1.8 0.8 1 0.8 1.8 14.5    
3x4 2.3 1 1 1.25 1.8 17.4    
3x6 2.8 1 1 1.25 1.8 18.4    
3x10 3.6 1 1 1.25 1.8 20.2    
3x16 4.5 1 1 1.6 1.8 22.8    
3x25 5.6 1.2 1 1.6 1.9 26    
3x35 6.7 1.2 1 1.6 1.9 28.5    
3x50 8 1.4 1 2 2 33.3    
3x70 9.4 1.4 1.2 2 2.1 37    
3x95 11 1.6 1.2 2 2.3 41.6    
3x120 12.4 1.6 1.2 2.5 2.4 45.9    
3x150 13.8 1.8 1.4 2.5 2.6 50.4    
3x185 15.3 2 1.4 2.5 2.7 54.8    
3x240 17.5 2.2 1.5 2.5 2.9 61.2    
3x300 19.5 2.4 1.6 2.5 3.1 66.8    
3x400 22.6 2.8 1.6 3.15 3.4 76.7    
3x500 25.2 2.8 1.8 3.15 3.7 83.6    
                 
Three cores+1(Galvanized steel wire armoured)    
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x10 +6 3.6 2.8 1 1 1 1.25 1.8 21.9
3x16 +10 4.5 3.6 1 1 1 1.6 1.8 24.2
3x25 +16 5.6 4.5 1.2 1 1 1.6 1.8 27.9
3x35 +16 6.7 4.5 1.2 1 1 1.6 1.9 30.8
3x50 +25 8 5.6 1.4 1.2 1 2 2 36.4
3x70 +35 9.4 6.7 1.4 1.2 1.2 2 2.1 40.1
3x95 +50 11 8 1.6 1.4 1.2 2.5 2.3 46.3
3x120 +70 12.4 9.4 1.6 1.4 1.4 2.5 2.4 50.3
3x150 +70 13.8 9.4 1.8 1.4 1.4 2.5 2.6 55
3x185 +95 15.3 11 2 1.6 1.4 2.5 2.7 60.3
3x240 +120 17.5 12.4 2.2 1.6 1.6 2.5 2.9 67

Four cores(Galvanized steel wire armoured)
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4x4 2.3 1 1 1.25 1.8 18.5
4x6 2.8 1 1 1.25 1.8 19.7
4x10 3.6 1 1 1.25 1.8 22.3
4x16 4.5 1 1 1.6 1.8 24.5
4x25 5.6 1.2 1 1.6 1.9 28.2
4x35 6.7 1.2 1 1.6 2 31.1
4x50 8 1.4 1 2 2.1 36.7
4x70 9.4 1.4 1.2 2 2.3 40.4
4x95 11 1.6 1.2 2.5 2.5 46.6
4x120 12.4 1.6 1.4 2.5 2.6 50.6
4x150 13.8 1.8 1.4 2.5 2.7 55.3
4x185 15.3 2 1.4 2.5 2.9 60.6
4x240 17.5 2.2 1.6 2.5 3.1 67.3
4x300 19.5 2.4 1.6 3.15 3.4 74.9
4x400 22.6 2.6 1.8 3.15 3.7 84.4
4x500 25.2 2.8 2 3.15 3.9 92.1

Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables
Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables
Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables
Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables
Nyry 0.6/1kv Low Voltage PVC Insulated Power Armoured Cables






 

Film Cutting Machine

The Smart Screen Protector Cutting Machine can help stores reduce the inventory of Screen Protectors. It is mainly used to cut Screen Protectors such as Mobile Phone Screen Protectors, Watch Screen Protectors, Tablet Screen Protectors, Pad Screen Protectors, and personalized fashion Back Films. It is very suitable for personal business or shop drainage.

Universal Screen Protector Cutting Machine has 20000+ cloud data of different specifications and models, adopts massive cloud database, and all data is updated synchronously in the state of networking. You'll have a full range of screen protector models on one machine and cut any Screen Protector model as needed without having to stock up on Screen Protectors for various phone models. No more losing customers due to missing models.

Screen Protector Cutting Machine,Protective Film Cutting Machine,Back Sticker Cutting Machine,Phone Sticker Cutting Machine, Film Cutting Machine

Shenzhen Jianjiantong Technology Co., Ltd. , https://www.tpuprotector.com